Gratis downloads
“Sharing will enrich everyone with more knowledge.”
- Ana Monnar
Gehoor en Evenwicht
Publicaties
Hier vind je de meest recente publicatielijst van de expertisecel Gehoor en Evenwicht.Bisgaard, N., Zimmer, S., Laureyns, M., & Groth, J. (2021). A model for estimating hearing aid coverage world-wide using historical data on hearing aid sales. International Journal of Audiology. 1-9. doi.org/10.1080/14992027.2021.1962551.
De Greve, G., van Dinther, J. J. S., Vanspauwen, R., Maryn, Y., Verstreken, M., Zarowski, A., & Offeciers, E. (2021). The MO-meatocanalplasty: Long-term results in the narrow external auditory canal with recurrent otitis externa or the inability to wear a hearing aid. European Archives of Oto-Rhino-Laryngology doi.org/10.1007/s00405-020-06599-z.
Feijen, J., Verguts, M., Van Gool, K., Maryn, Y., Bernaerts, A., De Foer, B., Zarowski, A., Offeciers, F. E., & van Dinther, J. J. S. (2021). Two cases of an atraumatic laryngeal fracture. Journal of Voice. doi.org/10.1016/j.jvoice.2021.05.022.
Kawamori, M., Best, L., & Laureyns, M. (2021). Standards for “safe listening”: past, present, and future. The Canadian Audiologist, 8(01).
Poels, L., Zarowski, A., Leblans, M., Vanspauwen, R., van Dinther, J., & Offeciers, E. (2021). Prognostic value of trial round window stimulation for selection of candidates for cochlear implantation as treatment for tinnitus. Journal of Clinical Medicine, 10(17):3793. doi.org/10.3390/jcm10173793.
Sismono, F., Mancini, L., Leblans, M., Goyens, J., De Greve, G., Schneiders, S., Beckers, K., Dirckx, J., De Foer, B., & Zarowski, A. (2021). Synchrotron radiation X-ray microtomography for the visualization of intra-cochlear anatomy in human temporal bones implanted with a perimodiolar cochlear implant electrode array. J Synchrotron Radiat., 28:327-332. doi.org/10.1107/S1600577520014952.
Sluydts, M., Bernaerts, A., Casselman, J. W., De Foer, B., Blaivie, C., Zarowski, A., van Dinther, J. J., Offeciers, E., Wuyts, F. L., & Vanspauwen, R. (2021). The relationship between cochleovestibular function tests and endolymphatic hydrops grading on MRI in patients with Menière's disease. European archives of Oto-Rhino-Laryngology, Advance online publication. doi.org/10.1007/s00405-021-06610-1.
van der Toom, H. F. E., van Dinther, J. J. S., Zarowski, A., Baazil, A. H. A., De Foer, B., Bernaerts, A., Casselman, J. W., & Offeciers, E. (2021). Radiological follow-up after the bony obliteration tympanoplasty in detecting residual cholesteatoma: Towards an optimal postoperative MR Imaging protocol. Otology & Neurotology. doi.org/10.1097/MAO.0000000000003348.
van Waegeningh, H. F., van Dinther, J. J. S., Vanspauwen, R., Zarowski, A., & Offeciers, E. (2021). The bony obliteration tympanoplasty in cholesteatoma: Safety, hygiene and hearing outcome: Allograft versus autograft tympanic membrane reconstruction. Eur Arch Otorhinolaryngol, 278(6):1805-1813. doi.org/10.1007/s00405-020-06258-3.
Zarowski, A., Fuentes, M. C., Schaudel, D., Leblans, M., De Coninck, L., Theunen, T., Vermeiren, A., Verschoren, L., van Dinther, J., & Offeciers, E. F. (2021). Intraoperative recordings of electromyogenic responses from the human stapedius muscle. Hearing Research, 408:108290. doi.org/10.1016/j.heares.2021.108290.
Baudelet, M., Van den Steen, L., Duprez, F., De Bodt, M., Deschuymer, S., Goeleven, A., Hutsebaut, I., Mariën, S., Meersschout, S., Nevens, D., Nuyts, S., Peeters, M., Specenier, P., Van den Brekel, M., van der Molen, L., Vandenbruaene, C., Vanderveken, O., van Dinther, J. J. S., Van Laer, C., Vauterin, T., Verstraete, H., & Van Nuffelen, G. (2020). Study protocol for a randomized controlled trial: Prophylactic swallowing exercises in head-and-neck cancer patients treated with (chemo)radiotherapy (PRESTO trial). Trials, 21(1):237. doi.org/10.1186/s13063-020-4171-0
Sluydts, M., Bernaerts, A., De Foer, B., Zarowski, A., van Dinther, J. J. S., Vanspauwen, R., & Offeciers, E. (2020). The sensitivity of the cVEMP-test in detecting a superior semicircular canal dehiscence and the influence of a coexisting incudal lysis: A case report.The Journal of International Advanced Otology, 16(1), 123–126. doi.org/10.5152/iao.2019.6790
van Dinther, J. J. S. (2020). Long Term Outcome of the Bony Obliteration Tympanoplasty in Cholesteatoma in Children and Adults: Safety - Hearing - Quality of Life. Nederlands Tijdschrift voor Keel - Neus - Oorheelkunde, 2.
van Dinther, J. J. S. (2020). Long Term Outcome of the Bony Obliteration Tympanoplasty in Cholesteatoma in Children and Adults: Safety - Hearing - Quality of Life. (Doctoral dissertation Radboud University, The Netherlands).
Zarowski, A., Molisz, A., Mylanus, E. A. M., Miserus, J. H. M., Leblans, M., van Dinther, J. J. S., Siebert, J., & Offeciers, E. F. (2020) Comparison of electrophysiological parameters between perimodiolar and lateral wall electrodes in paediatric cochlear implant users. European Archives of Oto-Rhino-Laryngology, 277(10), 2693–2699. doi.org/10.1007/s00405-020-05927-7
Bernaerts, A., Vanspauwen, R., Blaivie, C., van Dinther, J., Zarowski, A., Wuyts, F. L., . . . De Foer, B. (2019). The value of four stage vestibular hydrops grading and asymmetric perilymphatic enhancement in the diagnosis of Menière's disease on MRI. Neuroradiology, 61(4), 421-429. doi:10.1007/s00234-019-02155-7
Delrue, S., De Foer, B., van Dinther, J., Zarowski, A., Bernaerts, A., Vanspauwen, R., . . . Somers, T. (2019). The value of diffusion-weighted MRI in the long-term follow-up after subtotal petrosectomy for extensive cholesteatoma and chronic suppurative otitis media. Otology and Neurotology, 40(1), e25-e31. doi:10.1097/MAO.0000000000002049
Greve, G., Dinther, J. V., Maryn, Y., Vanspauwen, R., Zarowski, A., & Offeciers, E. (2019). Validity and test-retest reliability of the Dutch version of the chronic otitis media benefit inventory. Journal of International Advanced Otology, 15(1), 34-37. doi:10.5152/iao.2019.6339
Loos, E., Wuyts, L., Puls, T., Foer, B., Casselman, J. W., Bernaerts, A., . . . Somers, T. (2019). Cochlear erosion due to a facial nerve schwannoma. Journal of International Advanced Otology, 15(2), 330-332. doi:10.5152/iao.2019.5304
Molisz, A., Zarowski, A., Theunen, T., Vermeiren, A., De Coninck, L., Przewoźny, T., . . . Offeciers, E. F. (2019). Influence of stimulus presentation rate on intraoperative ECAP thresholds in cochlear implant users. International Journal of Audiology, 58(5), 296-300. doi:10.1080/14992027.2018.1558293
Vermeire, K., Knoop, A., De Sloovere, M., Bosch, P., & van den Noort, M. (2019). Relationship between working memory and speech-in-noise recognition in young and older adult listeners with age-appropriate hearing. Journal of Speech, Language and Hearing Resources, 62(9), 1-9. doi:10.1044/2019_JSLHR-H-18-0307
Bance, M., Zarowski, A., Adamson, R. A., & Casselman, J. W. (2018). New imaging modalities in otology. Advances in Otorhinolaryngoly, 81, 1-13. doi:10.1159/000485576
Busch, T., Sangen, A., Vanpoucke, F., & van Wieringen, A. (2018). Correlation and agreement between Language ENvironment Analysis (LENA™) and manual transcription for Dutch natural language recordings. Behaviour Research Methods, 50(5), 1921-1932. doi:10.3758/s13428-017-0960-0
Keustermans, W., Huysmans, T., Danckaers, F., Zarowski, A., Schmelzer, B., Sijbers, J., & Dirckx, J. J. J. (2018). High quality statistical shape modelling of the human nasal cavity and applications. Royal Society Open Science, 5(12), 181558. doi:10.1098/rsos.181558
Philips, B., Smits, C., Govaerts, P. J., Doorn, I., & Vanpoucke, F. (2018). Empowering senior cochlear implant users at home via a tablet computer application. American Journal of Audiology, 27(3S), 417-430. doi:10.1044/2018_AJA-IMIA3-18-0014
van Dinther, J. J. S., Coopman, R., Vercruysse, J. P., Somers, T., Zarowski, A., Vanspauwen, R., . . . Offeciers, F. E. (2018). The bony obliteration tympanoplasty in pediatric cholesteatoma: Long-term hearing results. Otology and Neurotology, 39(6), 715- 723. doi:10.1097/MAO.0000000000001846
Vanspauwen, R. (2018). Dizziness and (fear of) falling in the elderly: A few facts. Journal of International Advanced Otology, 14(1), 1-2. doi:10.5152/iao.2018.0201815
Busch, T., Vanpoucke, F., & van Wieringen, A. (2017). Auditory environment across the life span of cochlear implant users: Insights from data logging. Journal of Speech, Language and Hearing Resources, 60(5), 1362-1377. doi:10.1044/2016_jslhr-h-16-0162
De Ceulaer, G., Pascoal, D., Vanpoucke, F., & Govaerts, P. J. (2017). The use of cochlear's SCAN and wireless microphones to improve speech understanding in noise with the Nucleus6® CP900 processor. International Journal of Audiology, 56(11), 837-843. doi:10.1080/14992027.2017.1346305
Droessaert, V., Vanspauwen, R., Offeciers, E., Zarowski, A., Dinther, J. V., & Somers, T. (2017). Surgical treatment of acquired atresia of the external auditory ear canal. International Archives of Otorhinolaryngology, 21(4), 343-346. doi:10.1055/s-0037-1598604
Goehring, T., Bolner, F., Monaghan, J. J., van Dijk, B., Zarowski, A., & Bleeck, S. (2017). Speech enhancement based on neural networks improves speech intelligibility in noise for cochlear implant users. Hearing Research, 344, 183-194. doi:10.1016/j.heares.2016.11.012
Gérard, J. M., Demanez, L., Salmon, C., Vanpoucke, F., Walraevens, J., Plasmans, A., . . . Lefèbvre, P. (2017). Feasibility of an implanted microphone for cochlear implant listening. European Archives of Otorhinolaryngology, 274(3), 1383-1390. doi:10.1007/s00405-016-4410-x
Hsu, B. C., Vanpoucke, F., & van Wieringen, A. (2017). Listening effort through depth of processing in school-age children. Ear and Hearing, 38(5), 568-576. doi:10.1097/AUD.0000000000000436
Leyssens, L., Heinze, B., Vinck, B., Van Ombergen, A., Vanspauwen, R., Wuyts, F. L., & Maes, L. K. (2017). 'Standard' versus 'nose reference' electrode placement for measuring oVEMPs with air-conducted sound: Test-retest reliability and preliminary patient results. Clinical Neurophysiology, 128(2), 312-322. doi:10.1016/j.clinph.2016.11.023
Maryn, Y., Ysenbaert, F., Zarowski, A., & Vanspauwen, R. (2017). Mobile communication devices, ambient noise, and acoustic voice measures. Journal of Voice, 31(2), 248.e211-248.e223. doi:10.1016/j.jvoice.2016.07.023
van Dinther, J., Zarowski, A., Somers, T., & Offeciers, E. (2017). The MO-meatocanalplasty: A modification of the M-meatoplasty to address the superior quadrants and the bony canal. European Archives of Otorhinolaryngology, 274(9), 3291-3293. doi:10.1007/s00405-017-4626-4
Vanspauwen, R., Wuyts, F. L., Krijger, S., & Maes, L. K. (2017). Comparison of different electrode configurations for the oVEMP with bone-conducted vibration. Ear and Hearing, 38(2), 205-211. doi:10.1097/AUD.0000000000000372
Alsalman, O., Ost, J., Vanspauwen, R., Blaivie, C., De Ridder, D., & Vanneste, S. (2016). The neural correlates of chronic symptoms of vertigo proneness in humans. PLoS One, 11(4), e0152309. doi:10.1371/journal.pone.0152309
de Graaff, F., Huysmans, E., Qazi, O. U., Vanpoucke, F. J., Merkus, P., Goverts, S. T., & Smits, C. (2016). The development of remote speech recognition tests for adult cochlear implant users: The effect of presentation mode of the noise and a reliable method to deliver sound in home environments. Audiology and Neurotology, 21(S1), 48-54. doi:10.1159/000448355
Delrue, S., Verhaert, N., Dinther, J. V., Zarowski, A., Somers, T., Desloovere, C., & Offeciers, E. (2016). Surgical management and hearing outcome of traumatic ossicular injuries. Journal of International Advanced Otology, 12(3), 231-236. doi:10.5152/iao.2016.2868
Laplante-Lévesque, A., Abrams, H., Bülow, M., Lunner, T., Nelson, J., Riis, S. K., & Vanpoucke, F. (2016). Hearing device manufacturers call for interoperability and standardization of internet and audiology. American Journal of Audiology, 25(3S), 260-263. doi:10.1044/2016_AJA-16-0014
Plasmans, A., Rushbrooke, E., Moran, M., Spence, C., Theuwis, L., Zarowski, A., . . . Mauger, S. J. (2016). A multicentre clinical evaluation of paediatric cochlear implant users upgrading to the Nucleus(®) 6 system. International Journal of Pediatric Otorhinolaryngology, 83, 193-199. doi:10.1016/j.ijporl.2016.02.004
Sennaroğlu, L., Colletti, V., Lenarz, T., Manrique, M., Laszig, R., Rask-Andersen, H., . . . Polak, M. (2016). Consensus statement: Long-term results of ABI in children with complex inner ear malformations and decision making between CI and ABI. Cochlear Implants International, 17(4), 163-171. doi:10.1080/14670100.2016.1208396
Vanspauwen, R., Knoop, A., Camp, S., van Dinther, J., Erwin Offeciers, F., Somers, T., . . . Blaivie, C. (2016). Outcome evaluation of the dizziness handicap inventory in an outpatient vestibular clinic. Journal of Vestibular Research, 26(5-6), 479-486. doi:10.3233/VES-160600
Vercruysse, J. P., van Dinther, J. J., De Foer, B., Casselman, J., Somers, T., Zarowski, A., . . . Offeciers, E. (2016). Long-term results of troublesome CWD cavity reconstruction by mastoid and epitympanic bony obliteration (CWR-BOT) in adults. Otology and Neurotology, 37(6), 698-703. doi:10.1097/MAO.0000000000001006
Vermeire, K., Knoop, A., Boel, C., Auwers, S., Schenus, L., Talaveron-Rodriguez, M., . . . De Sloovere, M. (2016). Speech recognition in noise by younger and older adults: Effects of age, hearing loss, and temporal resolution. Annals of Otology, Rhinology and Laryngology, 125(4), 297-302. doi:10.1177/0003489415611424
Vickers, D., Degun, A., Canas, A., Stainsby, T., & Vanpoucke, F. (2016). Deactivating cochlear implant electrodes based on pitch information for users of the ACE strategy. Advances in Experimental Medicine and Biology, 894, 115-123. doi:10.1007/978-3-319-25474-6_13
Buijs, E. F., Theunisse, H. J., Mulder, J. J., van den Hoogen, F. J., Offeciers, E. F., Zarowski, A. J., & Mylanus, E. A. (2015). The use of gentamicin-impregnated collagen sponges (Garacol®/Duracoll®) in cochlear implant infections: our experience in four cases. Clinical Otolaryngology, 40(5), 492-495. doi:10.1111/coa.12417
Delrue, S., De Foer, B., van Dinther, J., Zarowski, A., Somers, T., Casselman, J., & Offeciers, E. (2015). Handling an isolated malleus handle fracture: Current diagnostic work-up and treatment options. Annals of Otology, Rhinology & Laryngology, 124(3), 244- 249. doi:10.1177/0003489414550240
Maryn, Y., & Zarowski, A. (2015). Calibration of clinical audio recording and analysis systems for sound intensity measurement. American Journal of Speech Language Pathology, 24(4), 608-618. doi:10.1044/2015_AJSLP-14-0082
Molisz, A., Zarowski, A., Vermeiren, A., Theunen, T., De Coninck, L., Siebert, J., & Offeciers, E. F. (2015). Postimplantation changes of electrophysiological parameters in patients with cochlear implants. Audiology and Neurotology, 20(4), 222-228. doi:10.1159/000377615
van Dinther, J., Droessaert, V., Camp, S., Vanspauwen, R., Maryn, Y., Zarowski, A., . . . Offeciers, E. (2015). Validity and test-retest reliability of the Dutch version of the Chronic Otitis Media Questionnaire 12 (COMQ-12). Journal of International Advanced Otology, 11(3), 248-252. doi:10.5152/iao.2015.1701
van Dinther, J. J., Vercruysse, J. P., Camp, S., De Foer, B., Casselman, J., Somers, T., . . . Offeciers, E. (2015). The bony obliteration tympanoplasty in pediatric cholesteatoma: Long-term safety and hygienic results. Otology and Neurotology, 36(9), 1504-1509. doi:10.1097/MAO.0000000000000851
Adams, D., Ajimsha, K. M., Barberá, M. T., Gazibegovic, D., Gisbert, J., Gómez, J., … Zarowski, A. (2014). Multicentre evaluation of music perception in adult users of Advanced Bionics cochlear implants. Cochlear Implants International, 15(1), 20-26. doi:10.1179/1754762813Y.0000000032
Bogaerts, M., Waterval, J., van Dinther, J., Somers, T., Zarowski, A., & Offeciers, F. E. (2014). Treatment of traumatic stapediovestibular luxation: case report with the introduction of a new technique and review of literature. Otology and Neurotology, 35(4), 582-588. doi:10.1097/MAO.0000000000000322
Nehmé, A., El Zir, E., Moukarzel, N., Haidar, H., Vanpoucke, F., & Arnold, L. (2014). Measures of the electrically evoked compound action potential threshold and slope in HiRes 90K(TM) users. Cochlear Implants International, 15(1), 53-60. doi:10.1179/1754762813Y.0000000039
Weerts, A. P., Vanspauwen, R., Fransen, E., Jorens, P. G., Van de Heyning, P. H., & Wuyts, F. L. (2014). Space motion sickness countermeasures: a pharmacological doubleblind, placebo-controlled study. Aviation, Space and Environmental Medicine, 85(6), 638-644.
Frijns, J. H., Snel-Bongers, J., Vellinga, D., Schrage, E., Vanpoucke, F. J., & Briaire, J. J. (2013). Restoring speech perception with cochlear implants by spanning defective electrode contacts. Acta Otolaryngolica, 133(4), 394-399. doi:10.3109/00016489.2012.754107
Weerts, A. P., Vanspauwen, R., Fransen, E., Jorens, P. G., Van de Heyning, P. H., & Wuyts, F. L. (2013). Baclofen affects the semicircular canals but not the otoliths in humans. Acta Otolaryngologica, 133(8), 846-852. doi:10.3109/00016489.2013.782615
Snel-Bongers, J., Briaire, J. J., Vanpoucke, F. J., & Frijns, J. H. (2012). Spread of excitation and channel interaction in single- and dual-electrode cochlear implant stimulation. Ear and Hearing, 33(3), 367-376. doi:10.1097/AUD.0b013e318234efd5
Vanpoucke, F. J., Boermans, P. P., & Frijns, J. H. (2012). Assessing the placement of a cochlear electrode array by multidimensional scaling. IEEE Transactions on Biomedical Engineering, 59(2), 307-310. doi:10.1109/TBME.2011.2173198
Weerts, A. P., De Meyer, G., Pauwels, G., Vanspauwen, R., Dornhoffer, J. L., Van de Heyning, P. H., & Wuyts, F. L. (2012). Pharmaceutical countermeasures have opposite effects on the utricles and semicircular canals in man. Audiology and Neurotology, 17(4), 235-242. doi:10.1159/000337273
Zhao, Y. C., Somers, T., van Dinther, J., Vanspauwen, R., Husseman, J., & Briggs, R. (2012). Transmastoid repair of superior semicircular canal dehiscence. Journal of Neurological Surgery - Part B, Skull Base, 73(4), 225-229. doi:10.1055/s-0032- 1312713
Buechner, A., Beynon, A., Szyfter, W., Niemczyk, K., Hoppe, U., Hey, M., . . . Smoorenburg, G. (2011). Clinical evaluation of cochlear implant sound coding taking into account conjectural masking functions, MP3000™. Cochlear Implants International, 12(4), 194-204. doi:10.1179/1754762811Y0000000009
Jereczek-Fossa, B. A., Rondi, E., Zarowski, A., D'Onofrio, A., Alterio, D., Ciocca, M., . . . Orecchia, R. (2011). Prospective study on the dose distribution to the acoustic structures during postoperative 3D conformal radiotherapy for parotid tumors: dosimetric and audiometric aspects. Strahlentherapie und Onkologie, 187(6), 350- 356. doi:10.1007/s00066-011-2170-5
Nooij, S. A., Vanspauwen, R., Bos, J. E., & Wuyts, F. L. (2011). A re-investigation of the role of utricular asymmetries in Space Motion Sickness. Journal of Vestibular Research, 21(3), 141-151. doi:10.3233/VES-2011-0400
Rompaey, V. V., Dinther, J., Zarowski, A., Offeciers, E., & Somers, T. (2011). Fundus obliteration and facial nerve outcome in vestibular schwannoma surgery. Skull Base, 21(2), 99-102. doi:10.1055/s-0030-1270211
Sennaroğlu, L., Colletti, V., Manrique, M., Laszig, R., Offeciers, E., Saeed, S., . . . Konradsson, K. (2011). Auditory brainstem implantation in children and nonneurofibromatosis type 2 patients: a consensus statement. Otology and Neurotology, 32(2), 187-191. doi:10.1097/MAO.0b013e318206fc1e
Snel-Bongers, J., Briaire, J. J., Vanpoucke, F. J., & Frijns, J. H. (2011). Influence of widening electrode separation on current steering performance. Ear and Hearing, 32(2), 221-229. doi:10.1097/AUD.0b013e3181f8c0fe
van Dinther, J. J., Van Rompaey, V., Somers, T., Zarowski, A., & Offeciers, F. E. (2011). Prognostic significance of electrophysiological tests for facial nerve outcome in vestibular schwannoma surgery. B-ENT, 7(2), 115-119.
Van Rompaey, V., Claes, G., Verstraeten, N., van Dinther, J., Zarowski, A., Offeciers, E., & Somers, T. (2011). Skin reactions following BAHA surgery using the skin flap dermatome technique. European Archives of Otorhinolaryngology, 268(3), 373-376. doi:10.1007/s00405-010-1366-0
Vanspauwen, R., Weerts, A., Hendrickx, M., Buytaert, K. I., Blaivie, C., Jorens, P. G., . . . Wuyts, F. L. (2011). No effects of anti-motion sickness drugs on vestibular evoked myogenic potentials outcome parameters. Otology and Neurotology, 32(3), 497- 503. doi:10.1097/MAO.0b013e31820d94d0
Zarowski, A. J., Verstraeten, N., Somers, T., Riff, D., & Offeciers, E. F. (2011). Headbands, testbands and softbands in preoperative testing and application of bone-anchored devices in adults and children. Advances in Otorhinolaryngology, 71, 124-131. doi:10.1159/000323728
Battmer, R. D., Dillier, N., Lai, W. K., Begall, K., Leypon, E. E., González, J. C., . . . Smoorenburg, G. F. (2010). Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the cochlear nucleus CI24RE device: Relation to perceptual threshold and loudness comfort profiles. International Journal of Audiology, 49(9), 657-666. doi:10.3109/14992021003801471
Berenstein, C. K., Vanpoucke, F. J., Mulder, J. J., & Mens, L. H. (2010). Electrical field imaging as a means to predict the loudness of monopolar and tripolar stimuli in cochlear implant patients. Hearing Research, 270(1-2), 28-38. doi:10.1016/j.heares.2010.10.001
Buytaert, K. I., Nooij, S. A., Neyt, X., Migeotte, P. F., Vanspauwen, R., Van de Heyning, P. H., & Wuyts, F. L. (2010). A new model for utricular function testing using a sinusoidal translation profile during unilateral centrifugation. Audiology and Neurotology, 15(6), 343-352. doi:10.1159/000289577
Buytaert, K. I., Vanspauwen, R., Van de Heyning, P. H., & Wuyts, F. L. (2010). Reliability of utricular function testing sinusoidal translation profile during unilateral centrifugation. Fiziol Cheloveka, 36(3), 31-38.
Hinoul, P., Vanspauwen, R., Smajda, S., & Roovers, J. P. (2010). The Posterior Intravaginal Slingplasty treatment for apical prolapse: 3 years experience in a single centre setting. Facts, Views & Vision in Obgyn, 2(1), 1-8.
Nogueira, W., Vanpoucke, F., Dykmans, P., De Raeve, L., Van Hamme, H., & Roelens, J. (2010). Speech recognition technology in CI rehabilitation. Cochlear Implants International, 11(S1), 449-453. doi:10.1179/146701010X12671177204507
Topsakal, V., Hilgert, N., van Dinther, J., Tranebjaerg, L., Rendtorff, N. D., Zarowski, A., . . . van de Heyning, P. (2010). Genotype-phenotype correlation for DFNA22: characterization of non-syndromic, autosomal dominant, progressive sensorineural hearing loss due to MYO6 mutations. Audiology and Neurotology, 15(4), 211-220. doi:10.1159/000255339
van Dinther, J. J., Vercruysse, J. P., De Foer, B., Somers, T., Zarowski, A., Casselman, J., & Offeciers, E. (2010). Subarcuate supralabyrinthine approach for supralabyrinthine petrosal cholesteatoma. Annals of Otology, Rhinology and Laryngology, 119(1), 42- 46. doi:10.1177/000348941011900108
Vanspauwen, R., Seman, E., & Dwyer, P. (2010). Survey of current management of prolapse in Australia and New Zealand. Australian and New Zealand Journal of Obstetrics and Gynaecology, 50(3), 262-267. doi:10.1111/j.1479-828X.2010.01145.x
Wesarg, T., Battmer, R. D., Garrido, L. C., Dillier, N., Garcia-Ibáñez, L., Hey, M., . . . Smoorenburg, G. F. (2010). Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipients of the Nucleus CI24RE device. International Journal of Audiology, 49(10), 775-787. doi:10.3109/14992027.2010.492401
Beijen, J., Casselman, J., Joosten, F., Stover, T., Aschendorff, A., Zarowski, A., . . . Mylanus, E. (2009). Magnetic resonance imaging in patients with meningitis induced hearing loss. European Archives of Otorhinolaryngology, 266(8), 1229-1236. doi:10.1007/s00405-009-0921-z
Frijns, J. H., Kalkman, R. K., Vanpoucke, F. J., Bongers, J. S., & Briaire, J. J. (2009). Simultaneous and non-simultaneous dual electrode stimulation in cochlear implants: evidence for two neural response modalities. Acta Otolaryngolica, 129(4), 433-439. doi:10.1080/00016480802610218
Hinoul, P., Roovers, J. P., Ombelet, W., & Vanspauwen, R. (2009). Surgical management of urinary stress incontinence in women: a historical and clinical overview. European Journal of Obstetrics & Gynaecology and Reproductive Biology, 145(2), 219-225. doi:10.1016/j.ejogrb.2009.04.020
Migeotte, P. F., Pattyn, N., Vanspauwen, R., Neyt, X., Acheroy, M., Van de Heyning, P., & Wuyts, F. L. (2009). Respiratory sinus arrhythmia on the ESA-short-arm human centrifuge. IEEE Engineering in Medicine and Biology Magazine, 28(6), 86-91. doi:10.1109/MEMB.2009.934618
Vanspauwen, R., Wuyts, F. L., & Van de Heyning, P. H. (2009). Vestibular evoked myogenic potentials: test-retest reliability and normative values obtained with a feedback method for the sternocleidomastoid muscle contraction. Journal of Vestibular Research, 19(3-4), 127-135. doi:10.3233/VES-2009-0358
Verbist, B. M., Ferrarini, L., Briaire, J. J., Zarowski, A., Admiraal-Behloul, F., Olofsen, H., . . . Frijns, J. H. (2009). Anatomic considerations of cochlear morphology and its implications for insertion trauma in cochlear implant surgery. Otology and Neurotology, 30(4), 471-477. doi:10.1097/MAO.0b013e3181a32c0d
Verstraeten, N., Zarowski, A. J., Somers, T., Riff, D., & Offeciers, E. F. (2009). Comparison of the audiologic results obtained with the bone-anchored hearing aid attached to the headband, the testband, and to the "snap" abutment. Otology and Neurotology, 30(1), 70-75. doi:10.1097/MAO.0b013e31818be97a
Bachelorproeven
Hier vind je de bachelorproeven met een score van 16 of meer van de expertisecel Gehoor en Evenwicht.
2020-2021
promotoren: M. Laureyns, P. van Doren
Rationale
In deze bachelorproef werden gehoorverlies, ANL-testresultaten, zelfgerapporteerde problemen en het algemeen auditief functioneren vergeleken met burn-out signalen. Daarnaast werd de test-hertestbetrouwbaarheid van de Burn-out Assessment Tool getoetst.
Methodiek
Aan deze pilootstudie namen 37 proefpersonen tussen 20 en 79 jaar deel. Bij elke proefpersoon werden drie tests en drie vragenlijsten afgenomen. De tests bestonden uit drempelaudiometrie, de manuele ANL-test en de ANL-zelftest. De vragenlijsten waren de EuroTrak vragenlijst, de vragenlijst Algemeen Auditief Functioneren en de Burn-out Assessment Tool. De Burn-out Assessment Tool (BAT) is een recente zelfbeoordelingsvragenlijst die de aanwezigheid van primaire en secundaire symptomen van burn-out weergeeft. Bij 19 proefpersonen werd de volledige testprocedure na gemiddeld 76 dagen herhaald om de test-hertestbetrouwbaarheid te evalueren.
Resultaten
Uit de resultaten bleken geringe correlaties met het voorkomen van burn-out signalen. De test-hertestbetrouwbaarheid varieerde per subschaal. De subschaal psychosomatische spanningsklachten en de totale BAT-score behaalden een goede betrouwbaarheid, de andere subschalen een acceptabele, twijfelachtige of onaanvaardbare betrouwbaarheid.
Conclusie
Het peilen naar het Acceptable Noise Level (ANL) zou waardevol kunnen zijn ter preventie van burn-out. Ten gevolge van de beperkte proefgroep zijn er echter geen significante verbanden gevonden, noch met gehoorverlies en tinnitus waarmee eerder wel meermaals significante verbanden zijn vastgesteld. Bij de BAT was de mate van betrouwbaarheid lager dan bij eerdere studies. Dit is mogelijks te verklaren doordat de betrouwbaarheidscoëfficiënten zelf niet meer betrouwbaar zijn als de proefgroep minder dan 50 proefpersonen telt. Grootschaliger onderzoek met een werkende proefgroep of een proefgroep met personen met burn-out is aangewezen.
promotoren: A. Zarowski, F. Sismono
Rationale
Het doel was meer klinisch inzicht bieden in de wijze waarop het elektrodetype en -positie invloed hebben op spraakverstaanbaarheid naar aanleiding van variabiliteit in spraakperformantie bij volwassen CI-patiënten.
Methodiek
Het betreft een kwantitatief, observationeel, retrospectief onderzoek. De gegevens van volwassen CI-patiënten in de periode van 1 januari 2011 tot 1 april 2019 werden gebruikt (n=215). De onderzochte factoren waren de NVA-foneemscores in stilte, 6 en 12 maanden postoperatief, elektrodetype en -positie. Gemiddelde voorkomens in de cochlea werden met elkaar vergeleken om na te gaan of het elektrodetype invloed heeft op de positie. Om de invloed van de elektrodepositie op spraakperformantie te onderzoeken, werden alle data van de NVA-foneemscores verwerkt middels de t-toets en ANOVA.
Resultaten
Bij 20% van alle implantaties (n=195) werd scaladislocatie vastgesteld waarbij de Midscala elektrode het hoogste aantal heeft (47%), gevolgd door de Contour Advance (24%), Slim Modiolar (11%), Flex28 (3%) en SlimJ (0%). Voor de hele populatie is er geen significant verschil tussen NVA-foneemscores met en zonder scaladislocatie (t-toets, α=.05). De NVA-foneemscores liggen bij de Midscala het laagst, maar er is geen significant verschil tussen de scores met en zonder scaladislocatie (t-toets, α=.05). Bij de Contour Advance is er wel een significant verschil op 6 maanden, maar niet op 12 maanden postoperatief (t-toets, α=.05).
Conclusie
Bij een scaladislocatie ziet men voor de Contour Advance op korte termijn een negatief effect op het spraakverstaan, dat zich stabiliseert op lange termijn. Verder onderzoek is nodig om dit effect bij de andere elektroden te bevestigen.
promotoren: M. Laureyns, P. van Doren
Rationale
Rationale: Deze bachelorproef wil nagaan in hoeverre een afwijkende afnameprocedure van de manuele Vlaamse ANL-test overeenkomt met de resultaten uit de literatuur.
Methodiek
Onze studie is een vooronderzoek met een kleinere proefgroep, zodat een eerste indruk verkregen kan worden over de nieuwe ANL-zelftest. Aan het onderzoek namen 37 proefpersonen deel. Alle proefpersonen waren tussen 20;00 en 79;11 jaar. Bij iedere proefpersoon werd drempelaudiometrie, de manuele ANL-test, de ANL-zelftest en enkele vragenlijsten afgenomen. Het hele onderzoek verliep in de thuissituatie van de proefpersoon. Deze bachelorproef focust op de resultaten van de manuele ANL-test en de eventuele correlaties met gehoorverlies. Verder wordt ook de test-hertestbetrouwbaarheid van de manuele ANL-test nagegaan.
Resultaten
De gemiddelde ANL-score verkregen via de manuele ANL-test is 8,7 dB. Uit de resultaten blijkt dat er geen significante verbanden zijn tussen gehoorverlies en de resultaten van zowel de manuele test als de hertest. Er is echter een slechte test-hertestbetrouwbaarheid (r = .55; p = <.001) van de manuele ANL-test. De afname van de manuele ANL-test blijkt significant langer te duren dan de ANL-hertest (p = .01).
Conclusie
Deze pilootstudie van de manuele ANL-test met een afwijkende afnameprocedure, namelijk afgenomen onder hoofdtelefoon, vertoont afwijkende resultaten in vergelijking met eerdere (Vlaamse) ANL-studies. De gemiddelde ANL-score ligt lager dan eerdere onderzoeken. Bovendien is er een slechte test-hertestbetrouwbaarheid, wat eveneens afwijkt van de resultaten uit de bestaande literatuur. Gezien de kleine en niet-normaal verdeelde proefgroep is verder onderzoek noodzakelijk.
promotoren: M. Laureyns, P. van Doren
Rationale
Deze pilootstudie heeft als doel een beeld te vormen van het verband tussen de EuroTrak-vragenlijst, de drempelaudiometrie, de ANL-resultaten en het zelfgerapporteerd gehoorverlies bij personen tussen 20;00 en 79;11 jaar.
Methodiek
Aan deze pilootstudie namen 37 proefpersonen deel. De testprocedure bestond uit een afname van de drempelaudiometrie, het tweemaal uitvoeren van de manuele ANL-test en tweemaal de automatische ANL-zelftest. Elke proefpersoon vulde drie vragenlijsten in: de EuroTrak-vragenlijst, de vragenlijst rond het algemeen auditief functioneren en de Burn-out Assessment Tool. Het verband tussen het zelf rapporteren van klachten (gehoorproblemen, zichtproblemen, hoge bloeddruk, rugklachten en tinnitus) en de drempelaudiometrie evenals het verband tussen de zelfgerapporteerde klachten en de ANL-resultaten werden bepaald. Ook werd het verband tussen de onderdelen van de EuroTrak-vragenlijst en het zelfgerapporteerd gehoorverlies nagegaan. Om de test-hertestbetrouwbaarheid van de EuroTrak-vragenlijst te onderzoeken, doorliepen negentien personen van deze proefgroep de testprocedure twee keer. Tussen de testmomenten was er een spreiding van gemiddeld 76 dagen.
Resultaten
De resultaten tonen aan dat er een significant verband is tussen een hogere gemiddelde gehoordrempel, een hoger meest comfortabel niveau en het zelf rapporteren van een gehoorprobleem. Daarnaast is er ook een significant verband tussen het zelf rapporteren van een gehoorprobleem en het ervaren van tinnitus. Een significant verband tussen het zelf rapporteren van een gehoorprobleem of van tinnitus en de ANL-resultaten werd niet gevonden. Verder vertonen de vragen omtrent gehoorproblemen en tinnitus in de EuroTrak-vragenlijst een zeer goede tot perfecte betrouwbaarheid.
Conclusie
De EuroTrak-vragenlijst is een goede vragenlijst om snel en efficiënt te achterhalen of een persoon zich al dan niet bewust is van zijn gehoorverlies. Het schept ook een beeld van bijkomende klachten naast het gehoorverlies. Daarnaast is het aangewezen om in de praktijk meer aandacht te schenken aan tinnitus en de impact ervan.
promotoren: W. D'haenens, F. Vanpoucke
Rationale
Een efficiënte communicatie komt slechts tot stand bij een goede spraakverstaanbaarheid en een lage luisterinspanning. Het effect van de klasakoestiek op de spraakverstaanbaarheid is al decennia gekend, terwijl de impact op de luisterinspanning een recent studieonderwerp is.
Methodiek
Dit retrospectief onderzoek analyseert de reactietijden verkregen tijdens de klassikale spraakaudiometrie in ruis, met een signaal-ruisverhouding (SNR) van + 9 tot - 9 dB, in een lokaal dat voldoet aan de normale eis van de norm NBN S 01-400-2. De zitplaatsen varieerden van 1,31 tot 4,56 m tot de bron. De proefpersonen ondergingen een gehoorscreening en ze beoordeelden de luisterinspanning subjectief per SNR.
Resultaten
De reactietijden zijn significant langer, de foneemscores significant hoger en de subjectieve luisterinspanning significant lager bij studenten Audiologie bij enkele SNR’s. Negatievere SNR’s gaan gepaard met langere reactietijden. Studenten Audiologie met een subjectief slecht spraakverstaan in lawaai hebben langere reactietijden bij + 9 dB SNR ten opzichte van studenten Audiologie met een goed spraakverstaan in lawaai. Langere reactietijden gaan gepaard met hogere scores op de subjectieve luisterinspanning. Bij - 9 dB SNR gaan hogere foneemscores gepaard met kortere reactietijden. De reactietijden zijn significant langer in een lokaal dat niet voldoet aan de normale eis van de norm NBN S 01- 400-2.
Conclusie
De SAM-tool is in staat om de objectieve luisterinspanning via de reactietijden afzonderlijk per student weer te geven. De reactietijd wordt beïnvloed door de klasakoestiek, zelfs indien de proefpersonen dit subjectief niet ervaarden. Dit benadrukt het belang van een gunstige klasakoestiek.
promotor: W. D'haenens
Rationale
Sinds 2014 is in België het M-decreet (nu begeleidingsdecreet) van kracht wat heeft gezorgd voor meer inclusie in het regulier onderwijs. Om voor optimale leer- en werkomstandigheden te zorgen voor alle leerlingen en leerkrachten kan de akoestiek in klaslokalen eenvoudig en goedkoop gecontroleerd worden met de ATMOS (Akoestische Thomas MOre Screeningtool). Deze tool bestaat uit de applicatie SoundOut en een video-ondersteund werkboek.
Methodiek
Uit eerder onderzoek bleek de SoundOut applicatie (NAL) in aanmerking te komen, omdat betrouwbare nagalmtijden bekomen werden. Om docenten zelfstandig en correct nagalmtijdmetingen te laten verrichten van hun klaslokaal werd een werkboek met ondersteunende video’s ontwikkeld. Bij dit kwalitatief onderzoek werd nagegaan hoe gebruiksvriendelijk een pilootversie van dit video-ondersteund werkboek werd bevonden door vier proefpersonen zonder audiologische of akoestische achtergrond.
Resultaten
Het werkboek werd over het algemeen duidelijk bevonden door deze vier proefpersonen. De video over het gebruik van de iPad kreeg de beste beoordeling. De video over het Excel-document kreeg de slechtste beoordeling. Het voornaamste verbeterpunt is een groter lettertype.
Conclusie
Grootschaliger onderzoek bij leerkrachten secundair en lager onderwijs is noodzakelijk om een representatief beeld te krijgen van het gebruiksgemak van het video-ondersteund werkboek. Het video-ondersteund werkboek dient nog uitgetest te worden in combinatie met de SoundOut applicatie. Verder onderzoek moet uitwijzen of deze combinatie kan leiden tot betrouwbare nagalmtijdmetingen in klaslokalen.
promotoren: A. Zarowski, F. Sismono
Rationale
Deze bachelorproef werd uitgevoerd met als doel meer inzicht in de klinisch audiologische praktijk te bieden. De invloed van de elektrodepositie en het elektrodetype op de spraakperformantie van volwassen cochleaire implantaat-patiënten werd nagegaan.
Methodiek
Het data-onderzoek werd uitgevoerd a.d.h.v. de verkregen gegevens uit de CI-database en het elektronisch patiëntendossier (EPD) van het Sint-Augustinusziekenhuis te Wilrijk. In totaal werden de data en testgegevens van 217 proefpersonen onderzocht. De statistische verwerking werd uitgevoerd a.d.h.v. de anova-toets, t-toetsen en Pearsoncorrelaties.
Resultaten
Qua gehoorsparing werd geen significant verschil gevonden tussen scaladislocaties en implantaties in de scala tympani. Uit het onderzoek naar de invloed van elektrodetypes blijkt dat het Midscala-elektrodetype slechter scoort dan andere elektrodetypes op vlak van postoperatieve foneemscores. De Pearsoncorrelatie werd uitgevoerd om het verband tussen de gemiddelde afstand van het elektrodecontact tot de gehoorzenuw en de foneemscores na te gaan. Uit de resultaten is gebleken dat de gemiddelde afstand van het elektrodecontact tot de gehoorzenuw enkel correleert met de foneemscores op 60dB SPL 6 maanden postoperatief (p = .031, r = -0.39) en vooral 50dB SPL 6 maanden postoperatief (p = .002, r = -0,56). Op zowel 70, 60 als 50dB SPL werd geen significantie bevonden op 12 maanden postoperatief.
Conclusie
Vervolgonderzoek is noodzakelijk om de behaalde resultaten te reproduceren met grotere aantallen aan proefpersonen.
promotoren: M. Laureyns, P. van Doren
Rationale
Deze bachelorproef ging het verband tussen de vragenlijst Algemeen Auditief Functioneren en drempelaudiometrie, de manuele ANL, de zelftest ANL en de EuroTrak-vragenlijst na. Ook de test-hertestbetrouwbaarheid voor de vragenlijst Algemeen Auditief Functioneren werd onderzocht.
Methodiek
Dit kwantitatief experimenteel pilootonderzoek telde 37 proefpersonen tussen 20;00 en 79;11 jaar. Met behulp van een iPad en geijkte hoofdtelefoon onderging elke proefpersoon drie audiologische testen (drempelaudiometrie, manuele ANL en zelftest ANL) en vulden ze drie vragenlijsten (vragenlijst Algemeen Auditief Functioneren, EuroTrak-vragenlijst en Burn-Out Assessment Tool) in. Om de test-hertestbetrouwbaarheid na te gaan, werd bij 19 proefpersonen de testprocedure herhaald.
Resultaten
Er werd een significant verband gevonden tussen de manuele ANL-score en de vraag rond spraakverstaan in stilte. Bij de zelftest ANL werden er significante verbanden gevonden tussen het MCL en de totaalscore en de vragen rond spraakverstaan in stilte en in ruis alsook tussen de ANL-score en de totaalscore en vragen omtrent spraakverstaan in ruis, focus en acceptatie van achtergrondlawaai. Er blijkt een acceptabele test-hertestbetrouwbaarheid te zijn voor de vraag rond lokalisatie. De andere vragen behaalden een twijfelachtige of slechte betrouwbaarheid.
Conclusie
Het zelf bepalen van de intensiteit bij de ANL-test resulteert in meer significante verbanden met de vragenlijst. Het onderzoek toonde een slechte test-hertestbetrouwbaarheid aan voor de vragenlijst. Dit is vermoedelijk het gevolg van de uitgevoerde interventies, namelijk de testprocedure zelf, de lange tijd die de proefpersonen hadden om over de vragen te reflecteren alvorens de vragenlijst voor de tweede keer werd beantwoord en het beperkt aantal proefpersonen.
2019-2020
promotor: Filiep Vanpoucke
Rationale
De normcurve van de TM-CVC19-lijsten is conform de normcurve van de Vlaamse NVA-lijsten (Nederlandse Vereniging voor Audiologie) wat betreft de vorm. Uit onderzoek (Van Herck, 2019) bleek de TM-CVC19 normcurve 7 dB naar rechts verschoven. De doelstelling van deze bachelorproef was om deze variatie zoveel mogelijk te minimaliseren en om de lijstequivalentie van het nieuwe woordmateriaal opnieuw te bepalen.
Methodiek
De pilootstudie richtte zich op de vermindering van de variatie door niveaucorrecties (in drie modes) toe te passen. De TM-CVC20-lijsten zijn op vier intensiteiten (dBSPL) aangeboden aan acht normaalhorenden tussen 18;00 en 25;00 jaar. Verder kregen vier proefpersonen de NVA-lijsten aangeboden om de audiocabine en de apparatuur te valideren. Bij de datacollectie, uitgevoerd om de lijstequivalentie na te gaan, zijn tot slot de TM-CVC20-lijsten aangeboden aan 32 proefpersonen op de intensiteiten van 15 tot 50 dBSPL in mode nul. Om de lijstequivalentie na te gaan, verwerkten de onderzoekers alle data descriptief en statistisch met behulp van SPSS Statistics 25 (IBM, 2017). De pilootstudie en de datacollectie zijn beiden kwantitatief experimentele onderzoeken. De validatie van de audiocabine is een kwantitatief observationeel onderzoek. Voor deze drie onderzoeken zijn de otoscopie, de tympanometrie, de tonale audiometrie en spraakaudiometrie uitgevoerd.
Resultaten
Het meest gevoelige punt van de equivalentietest ligt in deze studie rond 20 dBSPL (gemiddelde SRT = 19,94 dBSPL). Verder kwamen de normcurves van de NVA-lijsten in stilte goed overeen met de resultaten in de Thomas More audiocabine wat een goede kalibratie aantoont. Tot slot toonde zowel de One-Way ANOVA (p = .159) als de Kruskal-Wallis toets (p = .094) een niet-significant effect aan, wat inhoudt dat de lijsten equivalent zijn.
Conclusie
De lijsten in het TM-CVC20-corpus blijken equivalent te zijn. Dit onderzoek is van belang voor de audiologische praktijk wegens de voordelen die deze lijsten bieden. Langere equivalente lijsten verhogen de betrouwbaarheid, wat belangrijk is voor onder meer hoortoestelaanpassingen en auditieve revalidatie. Verder zijn de lijsten ook klinisch beter toepasbaar.
promotoren: Mark Laureyns, Paul Van Doren
Rationale
Dit onderzoek gaat de verdeling van de Client Oriented Scale of Improvement-doelstellingen in twee verschillende categorisaties na, zeven jaar nadat de afname van de Client Oriented Scale of Improvement-vragenlijst door audiologen verplicht werd door het Rijksinstituut voor ziekte- en invaliditeitsverzekering. Er werd onderzocht of er significante verschillen waren tussen geslacht, leeftijd, primaire en secundaire en SMART en non-SMART doelstellingen.
Methodiek
Er werd gebruik gemaakt van een geanonimiseerde dataset die voorzien werd door Amplifon en 500 Nederlandstalige proefpersonen bevatte, zowel eerste als ervaren hoortoestelgebruikers. De verwerking gebeurde aan de hand van Microsoft Excel en Graph Pad Prism 6.0 voor Windows.
Resultaten
De grootste categorie bij de verdeling in zestien clusters volgens Harvey Dillon bleek “gesprek met 1 of 2 in stilte”. Ook bij de verdeling in de vijf clusters uit het onderzoek van Clement en De Wit (2010) bleken de meeste doelstellingen tot “spraak in stilte” te behoren. Er werden bij beide categorisaties significante verschillen aangetoond op basis van leeftijd, geslacht, de prioriteit en het al dan niet SMART zijn van de doelstellingen. Er bleek een grote nood aan betere categorieën, hier werden enkele voorstellen rond gedaan.
Conclusie
Aan de hand van dit onderzoek werden de noden van een groot aantal hoortoestelgebruikers in kaart gebracht. Hierdoor kwam ook aan het licht dat er nood is aan een betere categorisatie om vergelijkend onderzoek te kunnen uitvoeren.
promotoren: Mark Laureyns, Paul Van Doren
Rationale
In deze bachelorproef bekeken we het gebruik van de Client Oriented Scale of Improvement (COSI) binnen het proces van hoortoestelaanpassing. We gingen na welke factoren een invloed hebben op de mate van verandering en het eindresultaat aangegeven in de COSI-vragenlijst.
Methodiek
We gebruikten de geanonimiseerde gegevens van 500 proefpersonen, waarna later drie proefpersonen werden uitgesloten. De proefpersonen werden verzameld door de vestigingen van Amplifon in Vlaanderen. De mediaan van de leeftijd (deze gebruiken we omdat de leeftijd van onze proefgroep niet normaal verdeeld is) van onze proefpersonen is 73 jaar, de verhouding van mannen en vrouwen is respectievelijk 54% en 46%.
Resultaten
Uit de resultaten concludeerden we dat er geen leeftijdseffect noch geslachtseffect is voor de mate van verandering en het eindresultaat. Doelen met betrekking tot “televisie/radio” resulteren in een hogere mate van verandering en eindresultaat in vergelijking met "spraak in lawaai" en "spraak in stilte" gerelateerde doelen. Doelen met betrekking tot "spraak in lawaai" resulteren in een lager eindresultaat vergeleken met "spraak in stilte" -doelen.
Conclusie
Audiologen moeten getraind worden om de COSI-doelstellingen specifieker op te stellen. Op deze manier kunnen de noden en behoeften van de cliënt nog beter in kaart gebracht worden en daaropvolgend de hoortoestellen beter afgesteld worden.
promotoren: Mark Laureyns, Paul Van Doren
Rationale
Deze bachelorproef wil de voorgaande onderzoeken van de EuroTrak (EHIMA) uitbreiden met focus op de relatie tussen het audiogram en zelf-gerapporteerde gehoorproblemen. Het wil een basis uitzetten voor Europees onderzoek.
Methodiek
Deze bachelorproef volgt een kwantitatief, cross-sectioneel onderzoeksdesign. De proefgroep bestond uit 430 respondenten, verdeeld over vier leeftijdscategorieën (45.00 tot 54.11 jaar, 55.00 tot 64.11 jaar, 65.00 tot 74.11 jaar en 75.00 tot 84.11 jaar). Alle respondenten vulden een aangepaste EuroTrak-vragenlijst (EHIMA), zes vragen omtrent algemeen auditief functioneren en de Burnout Assessment Tool (BAT) (Desart, Schaufeli, & De Witte, 2019) in. Bij iedere respondent werd vervolgens een tonaal audiogram en een spraak- in ruistest (Vanpoucke, 2018) afgenomen.
Resultaten
Er is een statistisch significant verband tussen zelf-gerapporteerde gehoorproblemen en de aanwezigheid van gehoorverlies volgens de World Health Organisation (WHO) (p = <.05). De gemeten graad van gehoorverlies volgens de WHO is voor alle leeftijdscategorieën en de beide geslachten significant hoger bij de respondenten met zelf-gerapporteerde gehoorproblemen dan zonder zelf-gerapporteerde gehoorproblemen (p = <.05). De gemeten graad van gehoorverlies is niet significant hoger bij de respondenten met diabetes mellitus dan de respondenten zonder diabetes mellitus ( p = ≥.05). Respondenten die zichzelf een slechte score geven op een vraag rond hoorbaarheid van zachte geluiden of geluiden op afstand, hebben een significant hoger gemiddeld gehoorverlies volgens de WHO (rs = -.55, p = <.001).
Conclusie
Het peilen naar zelf-gerapporteerde gehoorproblemen is waardevol, maar wordt beïnvloed door vele factoren en moet dus met voorzichtigheid geïnterpreteerd worden én ondersteund worden door andere audiometrische onderzoeken.
promotoren: Wendy D'Haenens, Filiep Vanpoucke
Rationale
Het doel van dit onderzoek was om na te gaan of het effect van de klasakoestiek in een lokaal dat niet voldoet aan de normale eis kan vastgesteld worden bij studenten hoger onderwijs aan de hand van een klassikale spraakaudiometrie.
Methodiek
De onderzoekers voerden een kwantitatief, observationeel, cross-sectioneel onderzoek uit bij 62 studenten hoger onderwijs, in twee lokalen van campus Sint-Andries van Thomas More te Antwerpen. Hierbij voerden ze een klassikale spraakaudiometrie uit bij verschillende SNR-waarden en bevroegen ook de luisterinspanning per SNR-waarde. De proefpersonen werden op verschillende afstanden van de geluidsbron geplaatst, ondergingen ook een gehoorscreening en vulden een vragenlijst in.
Resultaten
De scores op spraakverstaan en luisterinspanning verschillen significant bij verschillende SNR-waarden. Ook is er bij enkele SNR-waarden een verschil te zien in score en luisterinspanning tussen studenten met een zelfgerapporteerd normaal gehoor en een zelfgerapporteerd verminderd gehoor. Verder is er een significant verschil gevonden tussen de scores op spraakverstaan tussen een lokaal dat wel voldoet en een lokaal dat niet voldoet aan de normale eis volgens de NBN S 01-400-2. Dit was niet vastgesteld voor de luisterinspanning.
Conclusie
Het spraakverstaan van studenten wordt wel degelijk beïnvloed door de klasakoestiek, zelfs wanneer die studenten dit zelf niet aangeven op basis van hun ervaren luisterinspanning. Bij het bouwen en inrichten van klaslokalen moet er dus voldoende aandacht besteed worden aan de klasakoestiek en dient die objectief gemeten te worden.